Starter for John Deere 250D, 260E, 300D, 310E, 3154G, 380GLC ROTA0471
Starter for John Deere 250D, 260E, 300D, 310E, 3154G, 380GLC ROTA0471
Starter for John Deere 250D, 260E, 300D, 310E, 3154G, 380GLC ROTA0471
Starter for John Deere 250D, 260E, 300D, 310E, 3154G, 380GLC ROTA0471
Starter for John Deere 250D, 260E, 300D, 310E, 3154G, 380GLC ROTA0471
Starter for John Deere 250D, 260E, 300D, 310E, 3154G, 380GLC ROTA0471
Starter for John Deere 250D, 260E, 300D, 310E, 3154G, 380GLC ROTA0471

Starter for John Deere 250D, 260E, 300D, 310E, 3154G, 380GLC ROTA0471

Item #: 410-52592

Order today to get this price.

$234.20
Next Day Air Shipping for
Order by 4pm EST, M-F
Order in the next hrs mins secs

Our parts specialists can help answer all your questions. For further assistance call (800) 753-2242

Have tax exempt status? Call 800-753-2242 to order.
DB Electrical starters deliver exceptionally fast and efficient starts.
  • Fast engine starts thanks to more torque from high quality magnets or field coils
  • Cleaner and drier inner workings with sealed housings that block performance-robbing residue
  • Upgraded copper and silver contacts enhance performance over aluminum or steel ones
  • A long service life and improved efficiency result from premium brushes and bushings
  • Factory direct, money saving starters typically priced significantly less than OEM counterparts
Check if this fits your vehicle
HOW TO FIND YOUR FITMENT
Two ways to ensure proper fitment
DO YOU KNOW YOUR
OEM PART NUMBER?
LOOK FOR YOUR
MAKE/ MODEL/ YEAR
Enter your make/model/year below to find the right part.
  • Product Info
  • Applications List
  • Part Replacement List
  • Policy Information
  • Reviews

Overview

Electrical Aftermarket Parts for Virtually Any Vehicle
DB Electrical is a leading source for rotating electrical products for autos, trucks, motorcycles, ATVs, farm tractors and many other vehicles. We stand behind every product with our total-confidence 1-year warranty. Yes, you have a full year to make sure your order meets your expectations.

Item Number: ROTA0471

100% Brand New Aftermarket Part From DB Electrical

Product Specs

Item ConditionAftermarket Part
Unit TypeStarter
KW4.8
RotationCW
Starter TypePLGR
Tooth Count10
Voltage24

Applications List

Select Make & Type
MAKE TYPE MODEL YEAR ENGINE
John DeereEngine - Industrial1270E
John DeereEngine - Industrial1270G
John DeereEngine - Industrial1470E
John DeereEngine - Industrial1470G
John DeereEngine - Industrial1910E
John DeereEngine - Industrial1910G
John DeereEngine - Industrial250D
John DeereEngine - Industrial260E
John DeereEngine - Industrial300D
John DeereEngine - Industrial310E
John DeereEngine - Industrial3154G
John DeereEngine - Industrial3156G
John DeereEngine - Industrial350GLC
John DeereEngine - Industrial3754G
John DeereEngine - Industrial3756G
John DeereEngine - Industrial380GLC
John DeereEngine - Industrial644K
John DeereEngine - Industrial670G
John DeereEngine - Industrial670GP
John DeereEngine - Industrial672G
John DeereEngine - Industrial672GP
John DeereEngine - Industrial7230R
John DeereEngine - Industrial724K
John DeereEngine - Industrial7260R
John DeereEngine - Industrial7280R
John DeereEngine - Industrial744K
John DeereEngine - Industrial770G
John DeereEngine - Industrial770GP
John DeereEngine - Industrial772G
John DeereEngine - Industrial772GP
John DeereEngine - Industrial803M
John DeereEngine - Industrial803MH
John DeereEngine - Industrial8120
John DeereEngine - Industrial8220
John DeereEngine - Industrial8235R
John DeereEngine - Industrial8260R
John DeereEngine - Industrial8285R
John DeereEngine - Industrial8310R
John DeereEngine - Industrial8310RT
John DeereEngine - Industrial8320
John DeereEngine - Industrial8335R
John DeereEngine - Industrial8335RT
John DeereEngine - Industrial8360R
John DeereEngine - Industrial8360RT
John DeereEngine - Industrial8420
John DeereEngine - Industrial848L
John DeereEngine - Industrial850JR
John DeereEngine - Industrial8520
John DeereEngine - Industrial853M
John DeereEngine - Industrial853MH
John DeereEngine - Industrial859M
John DeereEngine - Industrial859MH
John DeereEngine - Industrial870G
John DeereEngine - Industrial870GP
John DeereEngine - Industrial872G
John DeereEngine - Industrial872GP
John DeereEngine - Industrial903M
John DeereEngine - Industrial903MH
John DeereEngine - Industrial909M
John DeereEngine - Industrial909MH
John DeereEngine - Industrial948L
John DeereEngine - Industrial953M
John DeereEngine - Industrial959M
John DeereEngine - IndustrialS660
John DeereEngine - IndustrialS670
John DeereEngine - IndustrialS670HM

Replaces These Part Numbers

DENSO428000-6900
DENSO428000-6901
DENSO428000-9920

Frequently Asked Questions

Q: Why is my starter suddenly making a grinding noise?
A: Several things could produce grinding noises. First check to see if it has come loose. If so, install and replace any shims for proper drive gear to flywheel alignment and re-torque to OE specs. If it is still grinding, remove it for closer inspection, making sure to give the flywheel a detailed look. Replace components as needed.

Q: What is a gear reduction starter?
A: In short, it’s a super torque starter. It has a set of planetart gears that give it a lot of speed and the reduction of those gears gives it a lot of torque, providing the best of both worlds. These starters were previously known as Super Torque for racing applications for use on high compression engines. Today, however, nearly everything has a gear reduction starter on it. These starters are lighter, faster, smaller and use less CCA (cold cranking amps) to get going.

Q: How many amps does it take to start an engine?
A: It takes 500-800 CCA (cold cranking amps) on average. High compression engines will pull even more depending on compression ratios.

Q: Why am I hearing a whine or whizzing sound without the engine cracking?
A: The drive gear is slipping and not engaging the flywheel. Replacement is needed.

Q: Why does my starter keep running after the car starts?
A: It is either the solenoid or the ignition switch. You should consult a mechanic immediately.

Q: My car leaks oil on the starter, will that affect it?
A: Yes. An oil-soaked armature commutator and brushes will wear out much faster and you run the risk of a dead start burning up the field coils.

Q: Why does the battery cable on my starter smoke?
A: Resistance. Either from a weak, loose or corroded cable or a failing worn starter. Replace components as needed.

Q: Why does the starter quit working and turning over on my car when it’s hot?
A: It’s most likely a heat-soaked solenoid. Heat-soaked solenoids have much more internal resistance when hot. Replace if needed and add a heat shield and/or wrap the headers with heat barrier wrap.

Q: When do I need to replace my starter?
A: Replace your starter under any of these conditions. 1)If your engine doesn't crank constantly every time the key is turned. 2) If the engine will not turn over and you hear a loud click. 3) If the starter fails to turn off or grinds the entire drive. In summary, if you have a strong battery and any one of these conditions exist, you should replace your starter.

Customer Reviews

WARNING: California’s Proposition 65

Recommended Products

Keeping customers satisfied for over 35 years.

Customers keep returning because we keep delivering total satisfaction. Our key to success is selling parts that fit and perform like the originals. It's why so many mechanics make us their top choice.

  • Find The Right Part

    Use our advanced part finder or search by part number to find your part.

  • Same-Day Shipping

    Orders placed by 2pm EST will ship that same day.

  • Fast, Free Delivery

    Orders over $50 shipped FREE to the 48 adjoining U.S states.

  • Expert Advice

    Need help choosing your part? Please contact us for help.

Back To Top